下面介绍veritas netbackup备份软件的带库测试工具robtest及使用方法p630#robtest
Configured robots with local control supporting test utilities:
TLD(0) robotic path = /dev/ovpass0Robot Selection
—————
1) TLD 0
2) none/quit
Enter choice: 1Robot selected: TLD(0) robotic path = /dev/ovpass0Invoking robotic test utility:
/usr/openv/volmgr/bin/tldtest -rn 0 -r /dev/ovpass0opening /dev/ovpass0
MODE_SENSE complete
Enter tld commands (? returns help information)To exit the utility, type q or Q.init – Initialize element status
initrange
allow – Allow media removal
prevent – Prevent media removal
extend – Extend media access port
retract – Retract media access port
mode – Mode sense
m
pos
s [d|p|t|s [n]] [raw] – Read element status
inquiry – Display vendor and product ID
rezero – Rezero unit
inport – Ready inport (media access port)
debug – Toggle debug mode for this utility
test_ready – Send a TEST UNIT READY to the device
or transport (t#)
[#] is number of elements for d, s, p, or t
NOTE – drive # is 1 – Number of drives
slot # is 1 – Number of slots
media access port # is 1 – Number of media access port elements
transport # is 1 – Number of transports
MOVE_MEDIUM completeunload d1 –卸载d1磁带
Opening /dev/rmt1.1, on the local host, please wait…
Tape successfully SCSI unloaded, ready for SCSI2 unloadm d1 s44 –将磁带机转为磁带
Initiating MOVE_MEDIUM from address 256 to 4139
MOVE_MEDIUM complete