一、查看partition 状态
MP> cm
Enter HE to get a list of available commands
MP:CM> ps
Display detailed status of the selected MP bus device.
The following MP bus devices were found:
+—+—-+—–+——-+——-+———–+
| | | | | | |
| | | Sys | | IO | Bulk Pwr |
|Cab| MP |Bkpln| Cells |Chassis| Supplies |
| # |M S| |0 1 2 3| 0 1 |0 1 2 3 4 5|
+—+—-+—–+——-+——-+———–|
| 0 |* | * |* | * * |* * * |
+—+—-+—–+——-+——-+———–+
You may display detailed power and hardware status for the following items:
T – Cabinet
S – System Backplane
G – MP (Core I/O)
P – IO Chassis
C – Cell
Select Device: t
HW status for rp8400 cabinet : NO FAILURE DETECTED
Power switch is on
Right Door is closed
Top Door is closed
Left Door is closed
Total Power Available 3000 VA
Total Power Needed 1818 VA
Power Redundancy : redundant
Power Viability : viable
Power Status
—————+—–+——-+——-+———–+
| | | | |
| Sys | | IO | Bulk Pwr |
|Bkpln| Cells |Chassis| Supplies |
| |0 1 2 3| 0 1 |0 1 2 3 4 5|
—————+—–+——-+——-+———–|
Populated | * |* | * * |* * * |
Enabled | * |* | * |* * * |
Power OK | * |* | * |* * * |
Warning/Fault | | | | |
Attention LED | | | | |
AC Line status:
Line A0 Present
Line B0 Present
Line A1 NOT PRESENT
Line B1 NOT PRESENT
— Press
Front Fan Speed : normal
Rear Fan speed : normal
I/O Bay Fan Speed : normal
Temperature state : normal
Fan Redundancy : redundant
Overtemp Shutdown Enabled
| BPS | PCI |
| Fans | Fans |
| 0 1 2 3 4 5 | 0 1 2 3 4 5 |
+———–+————-+————-+
Populated | * * * | * * * * * * |
Failing | | |
Failed | | |
| Standby/Main Fans |
| 1 1 1 1 1 1 1 1 1 1 2 |
| 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 |
+———–+——————————————-+
Populated | * * * * * * * * * * * * * * * * * * * * * |
Failing | |
Failed | |
| Cell Fans |
| 0 1 2 3 4 |
+———–+———–+
Cell 0 | |
Populated | * * * * * |
Failing | |
Failed | |
二、测试RP8400的MP LAN 和FTP server 是否联通,并把firmware 文件放在ftp server 自己指定的目录下:/tmp/fw,然后:用命令解开
使用 “gunzip” 解压FW文件。
# gunzip PF_CKEYMAT063.tar.gz
使用 “tar” 解开 firmware 文件。
%
本文由风哥教程整理发布,仅用于学习测试使用,转载注明出处:http://www.fgedu.net.cn/10327.html